Faculty of Medicine, Shimane University
Shimane University Faculty of Medicine
Shimane Journal of Medical Science

アクセス数 : 2019
ダウンロード数 : 94
Shimane Journal of Medical Science 39 巻 4 号
2022-12 発行

Magnetic Resonance Imaging Based Evaluation of Diagnostic Accuracy of Dual-energy Computed Tomography for Intracranial High Density Areas After Mechanical Thrombectomy

江田 大武
木村 麗新
吉田 弘太郎
本文ファイル
Magnetic Resonance Imaging Based Evaluation of Diagnostic Accuracy of Dual-energy Computed Tomography for Intracranial High Density Areas After Mechanical Thrombectomy ( 1.15 MB )
内容記述
After mechanical thrombectomy (MT) for acute ischemic stroke, contrast extravasation may be observed. Therefore, the diagnosis of intracranial hemorrhage (ICH) as the complication is difficult via conventional computed tomography (CT). This study aimed to evaluate the diagnostic accuracy of dual-energy CT (DECT) in differentiating ICH from contrast extravasation after MT. A retrospective study was conducted on patients who underwent MT from January 2019 to May 2022. Single-energy CT and DECT were conducted to estimate the ICH immediately after MT. Diagnostic confirmation of ICH and the diagnostic accuracy of DECT were evaluated via magnetic resonance imaging (MRI). Fifty-eight patients were assigned to this study. One patient (1.7%) had symptomatic ICH, and 18 (31.0%) had asymptomatic. The diagnostic accuracy of DECT based on MRI was 52.6% for sensitivity and 97.4% for specificity. Although DECT has been indicated to have high specificity for diagnosing hemorrhage after MT, MRI-based studies of DECT need improvement.
内容記述
10.51010/sjms.39.4_135
Jalc DOI
権利情報
Faculty of Medicine, Shimane University