ファイル情報(添付) | |
タイトル |
信頼性設計法による監査廊の安全性の評価
|
タイトル |
Evaluation of Gallery Safety with Reliability-Based Design
|
タイトル 読み |
シンライセイ セッケイホウ ニヨル カンサロウ ノ アンゼンセイ ノ ヒョウカ
|
著者 | |
収録物名 |
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
|
巻 | 24 |
開始ページ | 199 |
終了ページ | 203 |
収録物識別子 |
ISSN 0370940X
|
内容記述 |
その他
Safety of fill-dam gallery is evaluated with AFOSM and PEM. The design sections based on serviceability limit state of thermal stress and allowable stress method are checked. As a result, the both sections have safety indices over 4 in ultimate limit state, then show enough safety. Especially, the amount of reinforcement in serviceability limit state of thermal stress is over-estimated. It is found that the proper amount of reinforcement is about O.2% at arch crown. Moreover, the partial safety factors on limit state design in Japan are reasonable values, if allowable safety index β_a = 4 and coefficient of variation with external load is lO%.
|
言語 |
日本語
|
資源タイプ | 紀要論文 |
出版者 |
島根大学農学部
Shimane University, Faculty of Agriculture
|
発行日 | 1990-12-21 |
アクセス権 | オープンアクセス |
関連情報 |
[NCID] AN00108015
|