File | |
Title |
クリープ温度応力解析法としての状態方程式法と流速法の比較
|
Title |
Comparison between State Theory Method and Rate of Flow Method for Creep Thermal Stress Analysis
|
Title Transcription |
クリープ オンド オウリョク カイセキホウ トシテノ ジョウタイ ホウテイシキホウ ト リュウソクホウ ノ ヒカク
|
Creator | |
Source Title |
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
|
Volume | 22 |
Start Page | 121 |
End Page | 125 |
Journal Identifire |
ISSN 0370940X
|
Descriptions |
Therrnal cracking within mass-concrete structures is one of themes of today's concrete technology. How to evaluate thermal stress that causes thermal cracking exactly is the most basic subject in it. Up to now, State theory method and Rate of flow method are proposed to apply F. E. M. thermal stress analysis. This paper describes precision and utility of these two methods. As a result, State theory method has question about creep Poisson's ratio of 0.5 and Rate of flow method generates slightly greater thermal stress.
|
Language |
jpn
|
Resource Type | departmental bulletin paper |
Publisher |
島根大学農学部
Shimane University, Faculty of Agriculture
|
Date of Issued | 1988-12-21 |
Access Rights | open access |
Relation |
[NCID] AN00108015
|