RC-集合住宅における床衝撃音遮音性能の調査

島根大学農学部研究報告 18 巻 80-87 頁 1984-12-20 発行
アクセス数 : 1245
ダウンロード数 : 777

今月のアクセス数 : 89
今月のダウンロード数 : 8
ファイル情報(添付)
d0030018n013.pdf 1.79 MB エンバーゴ : 2001-10-08
タイトル
RC-集合住宅における床衝撃音遮音性能の調査
タイトル
Survey of Impact Noise Isolation Capability of Floors in a Reinforced-Concrete Apartment Building
タイトル 読み
RC シュウゴウ ジュウタク ニオケル ユカ ショウゲキオン シャオン セイノウ ノ チョウサ
著者
高橋 徹
田中 千秋
塩田 洋三
収録物名
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
18
開始ページ 80
終了ページ 87
収録物識別子
ISSN 0370940X
内容記述
その他
A survey of floor performance under impact noise and the propagation of noise withina reinforced-concrete apartment building(for national government officials and their families) was undertaken. The apartment building has five floors and 30 units. The floor plan for two units is shown in Fig.1. The floor construction in the living room which is finished with wood flooring, and in one of the six-mat Tatami rooms(No. 2) is shown in Fig.2.
In the experiment, the noise source room is in apartment No.501, and the impact noise on the floor was recorded using 5 microphones. Noise sources used were as follows :
Tapping machine(IS0 140 and JIS A1418) ....Simulating footfalls
Tire (JIS A1418) .. simulating children's jumps
The frequency spectrum ofimpact sound level in apartment No.401 are shown in Fig.3. Attenuation of impact noise of floor using soft floor-finish materials are obtained only with the tapping machine and are shown in Figs.6 and 7. Tatami and thick carpet on wood floor are better than plywood floor with respect to impact noise. The distribution of impact sound level in the apartment buiding is show in Table 3. Linear regression equations for sound pressure levels on the logarithm of distance were computed, as shown in Fig 5. The slopes ranged from -25.6 to -33.9(dB/m) for the tapping machine, and from -31.6 to -42.1(dB/m) for tire dropping.
言語
日本語
資源タイプ 紀要論文
出版者
島根大学農学部
Shimane University, Faculty of Agriculture
発行日 1984-12-20
アクセス権 オープンアクセス
関連情報
[NCID] AN00108015