アクセス数 : 1112 件
ダウンロード数 : 217 件
この文献の参照には次のURLをご利用ください : https://doi.org/10.24568/31113
島根大学地球資源環境学研究報告 15 巻
1996-12-25 発行
表面電離型質量分析計,MAT262による岩石・鉱物試料のSr-Nd同位体組成の測定
Sr and Nd isotopic analyses,using a thermal ionization mass spectrometer MAT262
飯泉 滋
本文ファイル
c006015021.pdf
( 446 KB )
内容記述
Extraction methods of Rb, Sr, Sm and Nd from rocks and minerals are described. Sr isotope ratio of standard sample NBS987 was repeatedly measured for a long terrn, using a mass spectrometer MAT262 at the Department of Geoscience, Shimane University. The isotope ratio is in a restricted range from 0.710260±0.000009 (2σ) to 0.710285±0.000009 (2σ). Sr isotope ratio was measured for the same six samples at the Department of Geosience, Shimane University and the Institute for Study of the Earth's Interior,Okayama University. Each sample gave quite similar isotope ratio13;
About This Article
Doi
https://doi.org/10.24568/31113
Pages
Other Article
PP. 115 - 135
PP. 137 - 145