Title Transcription | カンサロウ ノ パイプクーリング ノ サイテキ イチ ノ ケントウ ニツイテ
|
Title Alternative (English) | A Study on Optimum Position of Pipe-Cooling in Fill-Dam Gallery
|
File | |
language |
jpn
|
Author |
Nonaka, Tsuguhiro
|
Description | Pipe-cooling is usually used for reducing thermal stress in fill-dam gallery. Sensitivity analysis can ask for the position of pipe-cooling. The elements which influence thermal cracking at both shoulder and arch crown were picked out on the result of sensitivity analysis, i.e., influence coefficient to thermal stress. As a result, the difference between the optimum position and the actually placed position is a little, and the optimum position shows closely spacing near the lower part of crown.
|