number of downloads : ?
Title Transcription
カンサロウ ノ パイプクーリング ノ サイテキ イチ ノ ケントウ ニツイテ
Title Alternative (English)
A Study on Optimum Position of Pipe-Cooling in Fill-Dam Gallery
File
language
jpn
Author
Nonaka, Tsuguhiro
Description
Pipe-cooling is usually used for reducing thermal stress in fill-dam gallery. Sensitivity analysis can ask for the position of pipe-cooling. The elements which influence thermal cracking at both shoulder and arch crown were picked out on the result of sensitivity analysis, i.e., influence coefficient to thermal stress. As a result, the difference between the optimum position and the actually placed position is a little, and the optimum position shows closely spacing near the lower part of crown.
Journal Title
Bulletin of the Faculty of Agriculture, Shimane University
Volume
23
Start Page
138
End Page
141
ISSN
0370940X
Published Date
1989-12-21
NCID
AN00108015
Publisher
島根大学農学部
Publisher Aalternative
Shimane University, Faculty of Agriculture
NII Type
Departmental Bulletin Paper
OAI-PMH Set
Faculty of Life and Environmental Science
他の一覧
このエントリーをはてなブックマークに追加