File | |
language |
eng
|
Author |
Watanabe, Koji
Nishio, Toshikazu
Kihara, Masahiro
Mori, Chuzo
|
Description | The reproducibility of the thermodilution method in anesthetized and conscious rats was analyzed. Cardiac outputs in anesthetized state were stable in each procedure. Those in conscious state, especially the first measurement, tended to be underestimated compared with those in anesthetized state. The difference between anesthetized and conscious states might be produced by the increased temperature of saline in the tube placed under the skin of the conscious rat. Therefore, if we exclude the value of the first measurement, the thermodilution method is reliable to measure cardiac output in conscious state.
|
Subject | reproducibility
thermodilution
conscious state
|
Journal Title |
Shimane journal of medical science
|
Volume | 9
|
Issue | 2
|
Start Page | 69
|
End Page | 74
|
ISSN | 03865959
|
ISSN(Online) | 24332410
|
Published Date | 1986-03-01
|
NCID | AA00841586
|
Publisher Aalternative | Shimane Medical University
|
NII Type |
Departmental Bulletin Paper
|
Format |
PDF
|
Text Version |
出版社版
|
OAI-PMH Set |
Faculty of Medicine
|
他の一覧 |