File | |
Title |
溶存酸素補給ノズルの性能
|
Title |
The Performance of Dissolved Oxygen Supplying Nozzle
|
Title Transcription |
ヨウゾン サンソ ホキュウ ノズル ノ セイノウ
|
Creator |
Iwao Toshio
Kitamori Chikane
Ito Norihiro
|
Source Title |
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
|
Volume | 21 |
Start Page | 134 |
End Page | 140 |
Journal Identifire |
ISSN 0370940X
|
Descriptions |
In hydroculture it is important to figure out the most effective method to supply oxygen to the root.
This paper is designed to study the factors to increase the supply of DO(dissolved oxygen) by using severaltypes of nozzles. The nozzles have been developed after our study of some commercialized nozzles. In the case of oriffice nozzle, we find that a maximum DO can be obtained through the adjustment of the oriffice in size and in number. Under the oriffice, the use of two meshes with 1.5(mm) apart from each mesh cause higher DO. In the case of venturi nozzle, it has also found that a combination of the reduced angle 90°and the extended angle 130°in venturi can generate a higher DO. |
Language |
jpn
|
Resource Type | departmental bulletin paper |
Publisher |
島根大学農学部
Shimane University, Faculty of Agriculture
|
Date of Issued | 1987-12-21 |
Access Rights | open access |
Relation |
[NCID] AN00108015
|