File | |
Title |
帯鋸目立機械の振動について(1)
|
Title |
On the Mechanical Vibration of Band-saw Sharpener(1)
|
Title Transcription |
オビノコ メタテ キカイ ノ シンドウ ニツイテ 1
|
Creator |
Sakurai Toshio
Takahashi Akira
Fujita Shinsuke
Ito Kuniaki
|
Source Title |
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
|
Volume | 1 |
Start Page | 87 |
End Page | 94 |
Journal Identifire |
ISSN 0370940X
|
Descriptions |
The main purpose of this investigation was to search out a suitable swaging condittion of band-saw tooth, by comparing the relations between the standard deviation of swage spread(kerf width) and the mechanical vibration level of band-saw sharpner.
Vibration level of grinding axis were measured by useing the following aparatus, and frequency c/s and amplitude mm were calculated from the recording waves. Accelero-meters. (capacity ±2g, ±5g) Dynamic strain amplifier. Electro magnetic oscillograph. The position of accelero-meter adheared are shown in photo 1~3. Results of our test for each sharpener in six factories are shown in Table 4, and Fig. 4 and main values of vibration level and standard deviations(δ) of setting spread are as follows, Amplitude 8~389×10^<-4>mm Firequency 13~77c/s δ of shaping condition 6.7~1.7 x 10^<-2>mm δ of sharpening condition 5.9~2.4 x 10^<-2>mm From these results, it was reduced that the final standard deviation of setting spread (kerf width) formed by sharpener would be determined by either δ of shaper condition for the tooth point or vibration level(V) of grinding axis, and the authers determind a next experimental formular for relation between δ and V. (Fig. 6) δ mm = 0.8 V+0.02 mm In this case, δ : final standard deviation of kerf width V = √<a^2_⊥ + a^2_//> a is amplitude (mm) of grinding axis |
Language |
jpn
|
Resource Type | departmental bulletin paper |
Publisher |
島根大学農学部
|
Date of Issued | 1967-12 |
Publish Type | Version of Record |
Access Rights | open access |
Relation |
[NCID] AN00108015
|