コンクリートの気泡組織に影響する要因と耐凍害性に関する研究

日本建築学会構造系論文集 Volume 73 Issue 634 Page 2061-2067 published_at 2008-12
アクセス数 : 970
ダウンロード数 : 151

今月のアクセス数 : 46
今月のダウンロード数 : 1
File
110007006456.pdf 1.04 MB エンバーゴ : 2015-08-23
Title
コンクリートの気泡組織に影響する要因と耐凍害性に関する研究
Creator
濱 幸雄
平野 彰彦
田畑 雅幸
Source Title
日本建築学会構造系論文集
Volume 73
Issue 634
Start Page 2061
End Page 2067
Journal Identifire
ISSN 13404202
Descriptions
The influence of various factors such as chemical admixture and mixing conditions on the air void system of concrete was investigated by the buoyancy method. When AE agent was used independently, the difference of quantity and quality of entrained air due to the type of AE agent was not recognized among 10 types of AE agent used in this study. However, when AE agent was used with superplasticizer, we could see big difference in air entraining due to the type of AE agent. Furthermore, the influence of mixing efficiency and grading of sand was also large besides AE agent. It was possible to control frost resistance by the appropriate quantity and quality of entrained air even if concrete was subjected to wetting/drying cycles. The section air quantity of diameter from 100 to 500 micrometer is especially effective to prevent frost damage of concrete.
Subjects
コンクリート ( Other)
化学混和剤 ( Other)
混練条件 ( Other)
気泡組織 ( Other)
浮力法 ( Other)
耐凍害性 ( Other)
Concrete ( Other)
Chemical Admixture ( Other)
Mixing Condition ( Other)
Air Void System ( Other)
Buoyancy Method ( Other)
Frost Resistance ( Other)
Language
jpn
Resource Type journal article
Publisher
一般社団法人日本建築学会
Architectural Institute of Japan
Date of Issued 2008-12
Rights
一般社団法人日本建築学会
本文データは学協会の許諾に基づきCiNiiから複製したものである
Publish Type Version of Record
Access Rights open access
Relation
[DOI] 10.3130/aijs.73.2061
[NCID] AN10438559
isVersionOf [NAID] http://ci.nii.ac.jp/naid/110007006456 isVersionOf