| File | |
| Title |
監査廊のパイプクーリングの最適位置の検討について
|
| Title |
A Study on Optimum Position of Pipe-Cooling in Fill-Dam Gallery
|
| Title Transcription |
カンサロウ ノ パイプクーリング ノ サイテキ イチ ノ ケントウ ニツイテ
|
| Creator | |
| Source Title |
島根大学農学部研究報告
Bulletin of the Faculty of Agriculture, Shimane University
|
| Volume | 23 |
| Start Page | 138 |
| End Page | 141 |
| Journal Identifire |
ISSN 0370940X
|
| Descriptions |
Abstract
Pipe-cooling is usually used for reducing thermal stress in fill-dam gallery. Sensitivity analysis can ask for the position of pipe-cooling. The elements which influence thermal cracking at both shoulder and arch crown were picked out on the result of sensitivity analysis, i.e., influence coefficient to thermal stress. As a result, the difference between the optimum position and the actually placed position is a little, and the optimum position shows closely spacing near the lower part of crown.
|
| Language |
jpn
|
| Resource Type | departmental bulletin paper |
| Publisher |
島根大学農学部
Shimane University, Faculty of Agriculture
|
| Date of Issued | 1989-12-21 |
| Access Rights | open access |
| Relation |
[NCID]
AN00108015
|