Disinfection of River Water Using an Electrodialytic Disinfection System

日本海水学会誌 Volume 51 Issue 3 Page 113-118 published_at 1997
アクセス数 : 1125
ダウンロード数 : 0

今月のアクセス数 : 46
今月のダウンロード数 : 0
Title
Disinfection of River Water Using an Electrodialytic Disinfection System
Creator
AKIBA Michihiro
SUZUKI Takashi
OHYA Haruhiko
Source Title
日本海水学会誌
Bulletin of the Society of Sea Water Science, Japan
Volume 51
Issue 3
Start Page 113
End Page 118
Journal Identifire
ISSN 0369-4550
EISSN 2185-9213
Descriptions
A new practical method for disinfecting drinking water has been developed using anelectrodialysis system with cation-and anion-exchange membranes. The effectiveness of the current densities and flow rates of river water containing bacteria cells passing through a desalting chamber has been studied for practicality.
Perfect devitalization of Tamagawa River water is possible using an electrodialysis system with a current density of 0.48 A·dm-2 and a flow rate of 0.6dm3·min-1, and which consumes 7.92 KWH per 1m3, Therefore, the cost of this system is about 160 yen per 1m3 which is slightly more expensive thanthe chlorine disinfection method.
Language
eng
Resource Type journal article
Publisher
日本海水学会
The Society of Sea Water Science, Japan
Date of Issued 1997
Access Rights metadata only access
Relation
[DOI] 10.11457/swsj1965.51.113
ニホン カイスイ ガッカイ