| ファイル情報(添付) | |
| タイトル | The Accuracy of a Non-invasive Liver Fibrosis Evaluation Method, Shear Wave Elastography: A Retrospective Pilot Study | 
| 著者 | 
                                    古谷 聡史
                                    
                         
                                    高下 成明
                                    
                         
                                    塚野 航介
                                    
                         
                                    Ogawa Sayaka
                                    
                         
                                    山之内 智志
                                    
                         
                                    楠 龍策
                                    
                         
                                    相見 正史
                                    
                         
                                    宮岡 洋一
                                    
                         
                                    藤代 浩史
                                    
                         
                                    山本 智彦
                                    
                         
                                    大沼 秀行
                                    
                         | 
| 収録物名 | Shimane Journal of Medical Science | 
| 巻 | 34 | 
| 号 | 2 | 
| 開始ページ | 47 | 
| 終了ページ | 53 | 
| 収録物識別子 | ISSN 03865959 EISSN 24332410 | 
| 内容記述 | 抄録・要旨 Objective: We aimed to evaluate the diagnostic accuracy of shear wave elastography( SWE) for the assessment of liver fibrosis in patients with liver disease. Methods: A total of 54 consecutive patients who underwent SWE measurement and liver biopsy were included. Receiver-operator characteristic (ROC) curves were constructed to calculate the area under the ROC curve( AUC) for F0-2 versus F3-4 and F0-3 versus F4. Results: Fibrosis scores estimated by SWE were F0 for 9 cases, F1 for 18 cases, F2 for 11 cases, F3 for 9 cases, and F4 for 7 cases. AUCs for severe fibrosis (F3 and F4) and cirrhosis (F4) were 0.931 (P < 0.001) and 0.916 (P < 0.001), respectively. Shear wave velocity correlated significantly with liver fibrosis obtained by liver biopsy( r = 0.679, P < 0.001). Conclusion: SWE is a useful and non-invasive technology to estimate liver fibrosis in liver disease regardless of etiology. | 
| 主題 | 
                                chronic liver disease
                             
                                liver fibrosis
                             
                                shear wave elastographycoronary
                             | 
| 言語 | 英語 | 
| 資源タイプ | 紀要論文 | 
| 出版者 | Faculty of Medicine, Shimane University 島根大学医学部 | 
| 発行日 | 2017-12-31 | 
| 権利情報 | Faculty of Medicine, Shimane University | 
| 出版タイプ | Version of Record(出版社版。早期公開を含む) | 
| アクセス権 | オープンアクセス | 
| 関連情報 | 
                                    [NCID]
                                    AA00841586
                             |