内容記述(抄録等)
A multicolor digital holographic inspection system achieving both automatic scanning sensing head and automatic correction of a distortion in the profile due to positional error of a sensing head has been applied to the inner surface of a straight brass pipe having artificial defects on its wall. To investigate the inner surface of the pipe, the sensing head consisting of a cone-shaped mirror (CSM) glued to an aluminum base in the pipe is illuminated by the collimated RGB laser beams from the outside of the pipe. In the system, by changing the wavelength of the illumination light and scanning the CSM in the pipe, data acquisitions and analysis are performed using a personal computer. It is shown that the pipe inspection, including a classification of defects, can be successfully conducted by comparing the multicolor intensity images and the height profile of inner surface of pipe.
主題
Digital holographic system
Holographic interferometry
Multiwavelength
Pipe inspection
掲載誌名
Optics and Lasers in Engineering
97
開始ページ
62
終了ページ
70
ISSN
0143-8166
発行日
2017-10
DOI
出版者
Elsevier Ltd
資料タイプ
学術雑誌論文
ファイル形式
PDF
著者版/出版社版
著者版
業績ID
e33903
部局
総合理工学部