内容記述(抄録等)
The influence of various factors such as chemical admixture and mixing conditions on the air void system of concrete was investigated by the buoyancy method. When AE agent was used independently, the difference of quantity and quality of entrained air due to the type of AE agent was not recognized among 10 types of AE agent used in this study. However, when AE agent was used with superplasticizer, we could see big difference in air entraining due to the type of AE agent. Furthermore, the influence of mixing efficiency and grading of sand was also large besides AE agent. It was possible to control frost resistance by the appropriate quantity and quality of entrained air even if concrete was subjected to wetting/drying cycles. The section air quantity of diameter from 100 to 500 micrometer is especially effective to prevent frost damage of concrete.
主題
コンクリート
化学混和剤
混練条件
気泡組織
浮力法
耐凍害性
Concrete
Chemical Admixture
Mixing Condition
Air Void System
Buoyancy Method
Frost Resistance
掲載誌名
日本建築学会構造系論文集
73
634
開始ページ
2061
終了ページ
2067
ISSN
13404202
発行日
2008-12
DOI
NCID
AN10438559
出版者
一般社団法人日本建築学会
出版者別表記
Architectural Institute of Japan