The shearing properties of compacted and normally/over-consolidated decomposed granite soil are investigated with triaxial compression tests with consoildated undrained condition and direct shear tests with constant pressure. All tests wre performed with inundated specimen.
The shearing strength of compacted soils with D-value greater than 95% is larger than that of normally consolidated soil but that of compacted soils with D-value smaller than 90% is less than that of normally consolidated soil. The strength parameters c' and φ' determined with(σ_1-σ_3)_<max> by CU triaxial testsare decreased with decrement of D-value but φ' determined with(σ'_1/σ'_3)___<max> are nearly constant. The strength parameters by direct shear tests are also decreased with decrement of D-value but those are fairly greater than those obtained by triaxial tests. Moisture contents wf of direct shear tests after the experimemts are fairly greater than those of triaxial tests. The linearrelations are obtained between wf and strength parameters.
最近の盛土工事においては重転圧機械を用いて締固めを行い,締固め面は硬く,重機の走行は容易なため,剪断強度は軟弱な正規圧密土より大きいものと思われている.これは締固めたままの状態では正しいが,降雨や地下水が浸透し,飽和状態になった後でも成り立つという実験的な検討は全くない.さらに締固め不十分の盛土が降雨にあうと非常に軟弱になり,場合によっては大きな沈下を生じることもある.これは締固め土が飽和状態では正規圧密状態かそれ以下の剪断強度しか持たない場合のあることを示唆している.また締固め土の剪断強度を正規圧密と過圧密の剪断強度を組み合わせて表示することも行われている.
最近,これらのことに疑問を抱き,同じ土を用いて締固め状態とぺーストからの正規圧密,過圧密状態での剪断特性の比較をはじめた.昨年は藤の森粘土を用いて比較実験をした.この結果,D値≧95%では水浸状態でも締固め土の方が大きな剪断強度を持つが,D値≦90%では正規圧密の方が剪断強度が大きくなることを示した.このような比較は1つの土を用いたのみではあまり意味をなさなず,各種の土性の土を用いて実験をする必要がある.今回は代表的な砂質土であるまさ土を用いて実験した.
砂質土の剪断強度は三軸圧縮試験によって多くは行われるが,今回は三軸圧縮試験とともに定圧一面剪断試験も行った.実験は締固めたままの非水浸と水が浸透した水浸状態で行うことが望ましいが,盛土の設計は危険な状態を想定して水浸状態の強度定数を用いることが多いため,水浸のみとした.