ファイル | |
言語 |
英語
|
著者 |
秦 利之
渋川 敏彦
山本 和彦
Nagahara, Yutaka
村尾 文規
北尾 学
|
内容記述(抄録等) | The antenatal ultrasonic and postnatal caliper measurements for biparietal diameters were carried out in 44 spontaneous vaginal deliveries (24 primiparas and 20 multiparas) and 12 deliveries by caesarean sections, in an attempt to assess the accuracy of ultrasonic cephalometry and recovery of the fetal moulding. Biparietal diameter determined ultrasonic measurement within 24 hours before labor was smaller than that of neonates by the caliper measurement within one hour after labor, by an average of 1.83mm in cases of caesarean sections, and each biparietal diameter in primiparas, multiparas, and caesarean sections showed a different transition.
|
主題 | ultrasonics
biparietal diameter
fetal moulding
|
掲載誌名 |
Shimane journal of medical science
|
巻 | 6
|
号 | 1
|
開始ページ | 21
|
終了ページ | 25
|
ISSN | 03865959
|
ISSN(Online) | 24332410
|
発行日 | 1982-06-01
|
NCID | AA00841586
|
出版者別表記 | Shimane Medical University
|
資料タイプ |
紀要論文
|
ファイル形式 |
PDF
|
著者版/出版社版 |
出版社版
|
部局 |
医学部
|
他の一覧 |